These dryers offer the highest efficiencies at varying flow conditions in a lightweight, compact design. No other dryer in the industry can offer the efficiency ratings achieved by the VF Series dryers in variable flow operation.
VF Series dryers are built with the patented Variable Flow heat exchanger, which allows for desired dew point performance regardless of flow variations. Typically, other dryers with mechanical moisture separators lose performance as compressed airflow velocity increases or decreases substantially around the nominal design point.
The VF Series high efficiency heat exchanger utilizes a three-step process to thoroughly remove condensed moisture from the chilled compressed air. This process provides a separation efficiency in excess of 98% throughout the dryer's entire flow range.
Model # |
Capacity @ CAGI* |
Connection Size |
kW Full Load (CAGI Conditions) |
Full Load Amps |
Height |
Width |
Depth |
Manufacturer |
---|---|---|---|---|---|---|---|---|
VF-75 | Capacity @ CAGI* N/A 75 CFM | Connection Size N/A 1 in | kW Full Load (CAGI Conditions) N/A 0.30 | Full Load Amps N/A 7.2 | Height N/A 22 in | Width N/A 24 in | Depth N/A 18 in | Manufacturer N/A AirCel |
VF-100 | Capacity @ CAGI* N/A 100 CFM | Connection Size N/A 1 in | kW Full Load (CAGI Conditions) N/A 0.50 | Full Load Amps N/A 10.20 | Height N/A 22 in | Width N/A 24 in | Depth N/A 18 in | Manufacturer N/A AirCel |
VF-125 | Capacity @ CAGI* N/A 125 CFM | Connection Size N/A 1 in | kW Full Load (CAGI Conditions) N/A 0.60 | Full Load Amps N/A 13.30 | Height N/A 22 in | Width N/A 24 in | Depth N/A 18 in | Manufacturer N/A AirCel |
VF-150 | Capacity @ CAGI* N/A 150 CFM | Connection Size N/A 1 in | kW Full Load (CAGI Conditions) N/A 0.60 | Full Load Amps N/A 13.30 | Height N/A 22 in | Width N/A 24 in | Depth N/A 18 in | Manufacturer N/A AirCel |
VF-200 | Capacity @ CAGI* N/A 200 CFM | Connection Size N/A 1-1/2 in | kW Full Load (CAGI Conditions) N/A 0.75 | Full Load Amps N/A 10.90 | Height N/A 30 in | Width N/A 36 in | Depth N/A 25 in | Manufacturer N/A AirCel |
VF-250 | Capacity @ CAGI* N/A 250 CFM | Connection Size N/A 1-1/2 in | kW Full Load (CAGI Conditions) N/A 1.12 | Full Load Amps N/A 4.70 | Height N/A 30 in | Width N/A 36 in | Depth N/A 25 in | Manufacturer N/A AirCel |
VF-300 | Capacity @ CAGI* N/A 300 CFM | Connection Size N/A 2 in | kW Full Load (CAGI Conditions) N/A 1.12 | Full Load Amps N/A 4.70 | Height N/A 30 in | Width N/A 36 in | Depth N/A 25 in | Manufacturer N/A AirCel |
VF-400 | Capacity @ CAGI* N/A 400 CFM | Connection Size N/A 2 in | kW Full Load (CAGI Conditions) N/A 1.50 | Full Load Amps N/A 5.10 | Height N/A 45 in | Width N/A 34 in | Depth N/A 45 in | Manufacturer N/A AirCel |
VF-500 | Capacity @ CAGI* N/A 500 CFM | Connection Size N/A 2 in | kW Full Load (CAGI Conditions) N/A 2.20 | Full Load Amps N/A 9.60 | Height N/A 45 in | Width N/A 34 in | Depth N/A 45 in | Manufacturer N/A AirCel |
VF-600 | Capacity @ CAGI* N/A 600 CFM | Connection Size N/A 3 in | kW Full Load (CAGI Conditions) N/A 2.60 | Full Load Amps N/A 9.60 | Height N/A 45 in | Width N/A 34 in | Depth N/A 45 in | Manufacturer N/A AirCel |
VF-800 | Capacity @ CAGI* N/A 800 CFM | Connection Size N/A 3 in | kW Full Load (CAGI Conditions) N/A 3.70 | Full Load Amps N/A 9.60 | Height N/A 48 in | Width N/A 38 in | Depth N/A 54 in | Manufacturer N/A AirCel |
VF-1000 | Capacity @ CAGI* N/A 1000 CFM | Connection Size N/A 3 in | kW Full Load (CAGI Conditions) N/A 4.50 | Full Load Amps N/A 9.30 | Height N/A 48 in | Width N/A 38 in | Depth N/A 54 in | Manufacturer N/A AirCel |
VF-1200 | Capacity @ CAGI* N/A 1200 CFM | Connection Size N/A 3 in | kW Full Load (CAGI Conditions) N/A 4.50 | Full Load Amps N/A 9.30 | Height N/A 48 in | Width N/A 38 in | Depth N/A 54 in | Manufacturer N/A AirCel |
VF-50 | Capacity @ CAGI* N/A 50 CFM | Connection Size N/A 3/4 in | kW Full Load (CAGI Conditions) N/A 0.20 | Full Load Amps N/A 4.94 | Height N/A 18 in | Width N/A 22 in | Depth N/A 15 in | Manufacturer N/A AirCel |
VF-60 | Capacity @ CAGI* N/A 60 CFM | Connection Size N/A 3/4 in | kW Full Load (CAGI Conditions) N/A 0.30 | Full Load Amps N/A 7.20 | Height N/A 22 in | Width N/A 22 in | Depth N/A 15 in | Manufacturer N/A AirCel |
VF-10 | Capacity @ CAGI* N/A 10 CFM | Connection Size N/A 3/4 in | kW Full Load (CAGI Conditions) N/A 0.19 | Full Load Amps N/A 4.94 | Height N/A 15 in | Width N/A 16 in | Depth N/A 16 in | Manufacturer N/A AirCel |
VF-15 | Capacity @ CAGI* N/A 15 CFM | Connection Size N/A 3/4 in | kW Full Load (CAGI Conditions) N/A 0.19 | Full Load Amps N/A 4.94 | Height N/A 15 in | Width N/A 16 in | Depth N/A 16 in | Manufacturer N/A AirCel |
VF-25 | Capacity @ CAGI* N/A 25 CFM | Connection Size N/A 3/4 in | kW Full Load (CAGI Conditions) N/A 0.19 | Full Load Amps N/A 4.94 | Height N/A 15 in | Width N/A 16 in | Depth N/A 16 in | Manufacturer N/A AirCel |
VF-40 | Capacity @ CAGI* N/A 40 CFM | Connection Size N/A 3/4 in | kW Full Load (CAGI Conditions) N/A 0.19 | Full Load Amps N/A 4.94 | Height N/A 18 in | Width N/A 22 in | Depth N/A 15 in | Manufacturer N/A AirCel |
VF-1600 | Capacity @ CAGI* N/A 1600 CFM | Connection Size N/A 4 FLG in | kW Full Load (CAGI Conditions) N/A 7.50 | Full Load Amps N/A 21.10 | Height N/A 65 in | Width N/A 54 in | Depth N/A 67 in | Manufacturer N/A AirCel |
VF-2000 | Capacity @ CAGI* N/A 2000 CFM | Connection Size N/A 4 FLG in | kW Full Load (CAGI Conditions) N/A 9.70 | Full Load Amps N/A 25.00 | Height N/A 65 in | Width N/A 54 in | Depth N/A 67 in | Manufacturer N/A AirCel |