• itelliflow

    Well known is the fact that compressed air, stored at higher pressures, can provide a capacitance effect for sudden high volume demands. Less known is that higher pressure storage, that is not properly controlled and managed, will result in not just the additional energy to compress to a higher pressure (0.5% energy for every 1% pressure increase), but also significantly higher air consumption from all compressed air users (in some cases up to12% more)!

    The application of Ingersoll Rand IntelliFlow control effectively uses system storage to compensate for high, random air usage and avoids the need to increase the entire system pressure. Similarly, the IntelliFlow control also eliminates the need for compreesors to be loaded start or short cycle due to the same high, random air usage.

     

    Features

    High volume low pressure drop design

    Electronic PID control of valve position

    Mounted controller with digital interface

    Mounted pressure transducer

    3-valve bypass

    Taps and gages for system audit instrumentation

     

    Benefits

    Increased productivity: optimize production air control

    Increased efficiency: optimize energy usage

    Increased reliability: eliminate compressor rapid cycling

    Reduced waste: lower pressure, less air consumption

     

    Technical Information

    Max Pressure: 150 psig (10 barg)

    Max Temperature: 150°F (65°C)

    Flange/Valve Sizes: 2 - 8 in (50 - 200 mm)

    Max Flow Capacity: 850 - 15900 cfm (24 - 450 m3/min)

    1 psig (0.07 barg) pressure drop in full open valve position

     

  • PacE

    As much as 20% to 60% of the energy used to operate compressed air systems is wasted! One of the major contributors to this waste is operating air systems at elevated pressures.

    Well known is the fact that compressed air, stored at higher pressures, can provide a capacitance effect for sudden hign volume demands. Less known is that higher pressure storage, that is not properly controlled and managed, will result in not just the additional energy to compress to a higher pressure (0.5% energy for every 1% pressure increase), but also significantly higher air consumption from all compressed air users (in some cases up to12% more)!

    The application of Ingersoll Rand PacE control effectively uses system storage to compensate for high, random air usage and avoids the need to increase the entire system pressure. Similarly, the PacE control also eliminates the need for compreesors to be false loaded or short cycle due to the same high, random air usage.

     

    Features

    High volume low pressure drop design

    Pneumatic control

    Mounted inlet/outlet pressure gages

    Simple installation

     

    Benefits

    Increased efficiency: optimize energy usage

    Increased productivity: optimize production air control

    Increased reliability: eliminate compressor rapid cycling

    Reduced waste: lower pressure, less air consumption

     

    Technical Information

    Max Pressure: 150 psig (10 barg)

    Max Temperature: 150°F (65°C)

    Flange/Valve Sizes: 0.5 - 2 in (13- 50 mm)

    Max Flow Capacity: 40 - 650 cfm (1 - 18 m3/min)

    Sensitivity: 0.2% of full span

    Repeatability: +/- 0.5% of full span

     

Certifications